52-year-old male with eosinophilic esophagitis for 10 years and persistent dysphagia. Dilation with a 15 mm bougie cap and biopsy forceps.
Experienced teaching points
Clinical Pearls
- Endoscopic dilation is a critical intervention for symptomatic esophageal stenosis in eosinophilic esophagitis.
- Bougie caps offer a visually guided method for dilation, allowing for controlled stretching and immediate assessment of mucosal integrity.
- Endoscope floppiness during bougie cap-assisted dilation can be mitigated by introducing an accessory, such as biopsy forceps, into the working channel to enhance scope stiffness.
- Direct visualization during dilation helps to minimize risks of perforation or extensive laceration, distinguishing it from blind dilation techniques.
- Small mucosal lacerations are an expected finding after effective esophageal dilation.
Get cases like this Saturday mornings. Free, no spam.
Final Diagnosis
Successful endoscopic dilation of esophageal stenosis in a patient with eosinophilic esophagitis was achieved using a bougie cap and biopsy forceps for increased scope stiffness.
Patient Demographics
A 52-year-old male.
Clinical History
- History of eosinophilic esophagitis for 10 years.
- Presented for follow-up endoscopy due to persistent dysphagia.
- Indication for endoscopy was evaluation and management of dysphagia related to eosinophilic esophagitis.
Endoscopic Findings
- Multiple fibrotic rings were observed in the esophagus.
- The esophageal mucosa appeared otherwise normal.
- The endoscope passed into the stomach without difficulty prior to dilation.
Endoscopic Technique
- Dilation was performed using a bougie cap.
- The endoscope with an attached 15 mm bougie cap (with graduated diameters of 13, 14, and 15 mm) was advanced into the esophagus.
- Gentle pressure was applied under direct visualization through the bougie cap.
- Initial advancement of the endoscope was met with resistance due to endoscope floppiness.
- A biopsy forceps was advanced through the working channel to provide stiffness to the endoscope.
- With the biopsy forceps in place, further pushing of the scope with the bougie cap was performed.
- Mucosal visualization during advancement showed mild ripping effects, which were expected.
- Successful dilation was achieved once the cap reached the stomach.
- Upon retrieval of the cap, the entire esophageal mucosa was clearly visualized, revealing small mucosal lacerations consistent with successful dilation.
Discussion
Eosinophilic esophagitis often leads to esophageal stenosis requiring endoscopic dilation to alleviate dysphagia.
Blind dilation techniques carry a significant risk of laceration and perforation, particularly in fibrotic eosinophilic esophagitis, as the mucosa is not visualized during the procedure.
Balloon dilation is a recognized safe method for esophageal dilation in eosinophilic esophagitis.
This case demonstrates the utility of a bougie cap for controlled, visually guided dilation.
The challenge of endoscope floppiness during dilation with a bougie cap was effectively overcome by inserting a biopsy forceps into the working channel, providing necessary stiffness for successful advancement and dilation.