GI Endoscopy · 2 min read
Endoscopic Retrograde Cholangiopancreatography for Recurrent Choledocholithiasis and Stent Removal Using a Forward-Viewing Gastroscope
64-year-old female patient, recurrent choledocholithiasis, and a stenosis a standard duodenoscope could not pass. A forward-viewing gastroscope with a transparent cap, stone extraction, and balloon-against-cap stent removal.
Experienced teaching points
Clinical Pearls
- A forward-viewing endoscope with a distal transparent cap can be successfully employed for endoscopic retrograde cholangiopancreatography in cases of severe, fibrotic antral stenosis where a conventional duodenoscope cannot advance.
- The transparent cap enhances endoscopic visualization and maneuverability in difficult anatomical situations.
- A technique for fully covered self-expanding metal stent removal involves inflating an extraction balloon proximal to the stent and pulling it back against the transparent cap.
- This stent removal maneuver can be particularly useful for stents that are otherwise challenging to grasp or have migrated.
- Adaptability in endoscope choice and technique is crucial for successful outcomes in complex endoscopic retrograde cholangiopancreatography procedures.
Get cases like this Saturday mornings. Free, no spam.
Patient Demographics
A 64-year-old female patient presented for elective endoscopic retrograde cholangiopancreatography.
Clinical History
- The patient had a history of recurring choledocholithiasis.
- A previous endoscopic retrograde cholangiopancreatography with stone extraction had been performed one year prior.
- During the previous procedure, a heavily fibrotic distal antrum and a very tight entrance stenosis, likely due to non-steroid injection, were noted, leading to the insertion of a fully covered metal stent.
- Three months prior to the current presentation, an endoscopic retrograde cholangiopancreatography was performed after dilation of the stenosis, but advancing the scope was challenging.
- The current endoscopy was indicated for recurrent choledocholithiasis and stent removal.
Endoscopic Findings
- Initial attempts to advance a standard duodenoscope across a severe, fibrotic distal antrum stenosis were unsuccessful despite through-the-scope over-the-wire balloon dilation.
- The stenosis was noted to be extremely fibrotic, posing a high risk of perforation with further dilation.
- Upon insertion of a therapeutic forward-viewing gastroscope with a transparent distal cap, it was possible to pass through the stenotic antrum.
- The pylorus was visualized and appeared normal.
- Following cannulation, multiple stones were identified in the common bile duct.
Endoscopic Technique
- Initial attempts to advance a standard duodenoscope were made, including dilation of the distal fibrotic antrum stenosis using a through-the-scope over-the-wire controlled radial expansion balloon.
- Due to the inability to advance the standard scope past the severe stenosis and concern for perforation, the procedure was switched to a therapeutic forward-viewing gastroscope with an attached transparent distal cap.
- The forward-viewing endoscope successfully traversed the distal entrance stenosis and advanced into the pylorus.
- Using a sphincterotome, the bile duct was cannulated, gaining access to the previously placed stent.
- After cannulation, the guidewire was advanced, the sphincterotome was removed, and an extraction balloon was passed over the wire into the bile duct.
- Multiple common bile duct stones were successfully removed.
- For stent removal, an extraction balloon was inflated proximal to the fully covered self-expanding metal stent.
- The inflated balloon was then pulled back towards the scope and the transparent cap, effectively compressing the stent against the cap and allowing its complete extraction.
Discussion
This case highlights the utility of a forward-viewing endoscope in challenging endoscopic retrograde cholangiopancreatography cases involving severe, fibrotic distal antrum stenosis.
The presence of a transparent distal cap facilitated navigation through the stricture and provided an improved field of view for cannulation and therapeutic maneuvers.
In situations where conventional duodenoscopes cannot advance past difficult strictures, a forward-viewing endoscope can offer a viable alternative, reducing the risk of complications such as perforation.
The technique for removing fully covered self-expanding metal stents by inflating an extraction balloon proximal to the stent and pulling it back against the transparent cap provides an effective method for stent retrieval, particularly when the stent has migrated or is difficult to grasp.
This approach avoids the need for specialized stent removal accessories and leverages standard extraction balloons.
Get the newsletter
Get the next case in your inbox.
One practical GI endoscopy case every Saturday morning. Free.
Topics
For your teaching file
Save this article as a PDF
Drop your email and we'll open a print-ready version you can save as a PDF. You'll also start getting our GI endoscopy newsletter Saturday mornings.